Multiparameter portable meter ProfiLine pH/Cond 3320

Multiparameter portable meter ProfiLine pH/Cond 3320

  • SKU: 2EA310
Request a Quote
  • Description

    ProfiLine pH/Cond 3320: Universal multi-parameter portable meter with two inputs for pH, mV, ISE and conductivity measurements for demanding applications

    Variants
    Art.-No. Name Content
    2EA310 ProfiLine pH/Cond 3320 Single unit in field case with buffers STP 4 und STP 7, 0,01 mol/l KCl, manual and batteries, cable
    2EA312 ProfiLine pH/Cond 3320 SET 2 Single unit in field case with SenTix® 41, TetraCon® 325, buffers STP 4 and STP 7, 0,01 mol/l KCl. manual, stand, beaker, batteries, cable

    Highlights:


    • Two inputs for the simultaneous measurement of pH/mV/ISE and conductivity
    • Backlit graphic display for the parallel display of the measured values
    • Perfect for monitoring process applications

    The pH/Cond 3320 has a robust, waterproof housing (IP67) and is equipped with a memory as well as a data logger with an adjustable interval between 1 s and 60 minutes. All entries contain GLP-supporting data, like the date, time and ID number. The modern, waterproof USB interface is used for easy and quick data transfers. It can be used almost anywhere - in process chemistry, Life Science, food and beverage industry all the way to the pharmaceutical industry (measurement of pH and conductivity according to pharmacopeia).

      Overview page portable meters

    Learn more about pH sensors:

     Blog: Which pH electrode do I need?

     Blog: What is pH?

     Blog: Calibration and adjustment of a pH electrode

  • Specifications
    ProfiLine pH/Cond 3320
    Art.-No. 2EA310, 2EA312
    Parameters pH, Conductivity/Salinity/spec. Resistance, TDS
    Channels 2
    Measuring range pH -2.000 … 19.999
    Accuracy pH +/- 1 digit +/- 0.005/ +/-0.01/0.1
    Measuring range Temperature - 5.0 ... + 105.0 °C
    Accuracy Temperature +/- 1 digit +/-0.1 K
    Measuring range mV -1250.0 ...+1250.0 / -2500...+2500 mV
    Accuracy mV +/- 1 digit +/- 0.3 mV/ +/- 1 mV
    Measuring range SAL 0.0 ... 70.0
    Measuring range Cond. 0.001 µS/cm ... 1000 mS
    Resolution conductivity bis 0.001 µS/cm
    Accuracy Measurements +/- 1 digit +/- 0.5 %
    TDS 0 ... 199.9 g/l
    Specific resistance 1.000 ... 1999 Ohm*cm
    Operating temperature -10 °C ... + 55 °C
    Protection class IP 67
    Data storage Manually: 200, Automatic: 5.000
  • Accessories

Downloads

  • Manuals

    pH/Cond 3320 (German)

    Taschengerät,
    Bedienungsanleitung

    pH/Cond 3320 (French)

    Handheld meter,
    Operating manual

    pH/Cond 3320 (Italian)

    Handheld meter,
    Short instructions

    pH/Cond 3320 (Spanish)

    Handheld meter,
    Operating manual
  • Handbooks / Whitepaper

    ISE-Handbook (English)

    Download ISE Handbook

    Content:

    • Basic information - ISE
    • Description of ion-selective electrodes
    • Sample preparation
    • Measurement methods
    • Maintenance and special information
    • and more...

    pH Handbook (English)

    A guide with helpful practical tips

    Download pH Handbook

    Contents:

    • Basic concepts of potentiometry and pH measurement
    • Structure of pH electrodes
    • Potentiometry of the pH electrode
    • Buffer solutions and safety in pH measurement
    • Measuring equipment and measuring set-up
    • Practical pH measurement
    • Recommendations for use, maintenance and care of electrode

    Conductivity Handbook (English)

    A guide with helpful practical tips 

    Download Conductivity Handbook

    Content:

    • Fundamentals - conductivity
    • Calibration and analytical quality assurance
    • Measurement and analytical quality assurance
    • New measurement technologies and specific applications
    • Optical oxygen measurement and more...
  • Software

    ProfiLine 3310, 3320, MonoLine 3310 IDS - Firmware Update - V1.67

    Because of continuous improvement of internal performance we always recommend using the latest firmware version. This update solves a problem in the calibration history. Please note: When installed except the current calibration the history will be deleted, if necessary, please make a copy!

    Firmware version after successful update:

    pH 3310 V1.29
    pH 3310 IDS V2.07
    Cond 3310 V1.34
    Cond 3310 IDS V2.06
    Oxi 3310 V1.26
    Oxi 3310 IDS V2.12
    Oxi 3315 V2.10
    pH/ION 3310 V1.06
    pH/Cond 3320 V1.09
    Multi 3320 V1.09
    Multi 3310 IDS V2.15

    Download and installation notes:

    The cable for the serial USB interface is part of the delivery.

    Version history – innovations

    •V1.67:
    General optimizations and minor bug fixes

    •V1.66:
    General optimizations and minor bug fixes

    •V1.65:
    General optimizations and minor bug fixes

    •V1.64:
    -Update recommended; solves a problem with oxygen measurement of the last version.

    •V1.63:
    -Update recommended; solves a problem with oxygen measurement of the last version.

    •V1.62:
    -Solves a problem when switching the meters on or off: If the meter does not turn on, first perform a reset: Please press simultaneously “Menu – Enter” and “On/Off”, this will boot the meter automatically (without losing data).

    MultiLab Importer-Setup32

    Software

    Version history – innovations

    V 1.25: MultiLab Importer (Excel Add-In for acquisition of measured data)

    • Allows measurement and data entry of barcoded sample-ID via PC-connected barcode Reader for Turb® 750, Turb 430® and photoFlex® Series

    V 1.24: MultiLab Importer (Excel Add-In for acquisition of measured data)

    • New: Includes now photometers and turbidity meter of pHotoFlex series, Turb 430 and Turb 750 models
    • General improvements

    V1.23: Enhancements for MultiLab Importer

    • New Download of OxiTop®-IDS measurement date possible (results and measurement parameters)
    • Enhancement at transfer of electrochemical measurement results.

    MultiLab Importer-Setup64

    Software

    Version history – innovations

    V 1.25: MultiLab Importer (Excel Add-In for acquisition of measured data)

    • Allows measurement and data entry of barcoded sample-ID via PC-connected barcode Reader for Turb® 750, Turb 430® and photoFlex® Series

    V 1.24: MultiLab Importer (Excel Add-In for acquisition of measured data))

    • New: Includes now photometers and turbidity meter of pHotoFlex series, Turb 430 and Turb 750 models
    • General improvements

    V1.23: Enhancements for MultiLab Importer

    • New Download of OxiTop®-IDS measurement date possible (results and measurement parameters)
    • Enhancement at transfer of electrochemical measurement results.

    Software Update Windows 10 VCP Driver

    VCP Driver, 
    MultiLine, inoLab, ProfiLine, HandyLab and Lab, 
    Software Update for Windows 10

  • Flyers / Brochures / Catalogues

    ProfiLine Handhelds (Flyer, English, 999045US)

    Flyer, 8 Pages, English, 999045US,
    "For pH, ISE, Dissolved oxygen and conductivity" 

Related Products

Close