The cost-effective solution for general water management, drinking water treatment and monitoring, or wastewater treatment.
The SenTix® 20-22 pH electrodes with their plastic shaft are particularly suitable for mobile (field) pH measurement. The cylindrical shape of the membrane is robust and the fiber diaphragm prevents clogging. With the gel electrolyte filling, these electrodes are low-maintenance and do not need to be refilled.Temperature compensation is carried out either manually or via an external temperature sensor.
The Sentix® 41-47 pH electrodes with their plastic shaft are particularly suitable for mobile (field) pH measurement. The cylindrical shape of the membrane is robust and the fiber diaphragm prevents clogging. With the gel electrolyte filling, these electrodes are low-maintenance and do not need to be refilled.
The SenTix® 51-57 pH electrodes with their plastic shaft are suitable for mobile (field) pH measurement as well as for pH measurement in the laboratory in water and aqueous solutions. The cylindrical shape of the membrane and the ceramic diaphragm are robust. These electrodes are refillable and respond quickly due to the liquid electrolyte and have various temperature sensors (see table “Connections & variants”).
The SenTix® 91 pH electrode has a length of 170 mm and, with its high-quality glass shaft, refillable 3 mol/l KCl liquid electrolyte and platinum diaphragm, is suitable for demanding measurements in the laboratory. The platinum wire diaphragm offers optimum electrolyte flow without clogging and the liquid electrolyte offers fast response times. The electrode can also be used in difficult samples. The spherical shape of the diaphragm offers constant measurement quality and low resistance due to the large surface area. This electrode has an NTC 30 kOhm temperature sensor.
The SenTix® 81-87 pH electrodes with their high-quality glass shaft and refillable 3 mol/l KCl liquid electrolyte and platinum diaphragm are suitable for demanding measurements in the laboratory. The platinum wire diaphragm offers optimum electrolyte flow without clogging and the liquid electrolyte offers fast response times. The electrodes can also be used in difficult samples. The cone shape of the membrane is impact-resistant and easy to clean. These electrodes have different temperature sensors (see table “Connections & variants”).
The SenTix® Top 41 & 46 electrodes are developed for a wide range of applications in the laboratory, field and process from wastewater to emulsions, solutions with proteins, suspensions to purely aqueous samples. This is achieved through the special mechanical and chemical resistance of the PEEK shaft as well as the process-proven components of the measuring and reference electrode.
ProfiLine pH 3110 analog pH portable meter
ProfiLine pH 3310: Professional analog pH/mV/temperature portable meter with built-in data logger function and mini-USB interface for precise, user-friendly measurement in the field.
Low maintenance pH measurement in polluted samples
pH measurement in small vessels
Analog pH electrodes for food measurement
Module for automatic compressed air cleaning, controlled by relays or the IQ SENSOR NET
Measuring range: 0.3 - 40.0 mg/l MoSample volume: 25mlNumber of tests: 100Cuvette: 20mm, 28mm roundUsable with PhotoLab® and pHotoFlex® Complies with:-Method: Thioglycolic acidCombicheck: -Batch certificate: on request
Measuring range: 0.02 - 1.00 mg/l MoSample volume: 10 mlNumber of tests: 25Cuvette: 16mm roundUsable with PhotoLab® and pHotoFlex® Complies with:-Method: Bromopyrogallol redCombicheck: -Batch certificate: yes
WTW_Xylem_4c.eps
Xylem_tag_4c_300dpi_wClearSpace.jpg
Thumbs.db
_IQ_Sensoren_siehe_unter_IQ_Sensor_Net
aaj06940
WTW_Xylem_4c_300dpi.jpg
WTW_Xylem_rgb_72dpi.gif
Xylem_tag_RGB_72dpi_wClearSpace.gif
Xylem_tag_RGB_72dpi_wClearSpace.jpg
WTW_Xylem_rgb_72dpi.tif
Xylem_tag_RGB_72dpi_wClearSpace.tif
WTW_Xylem_rgb_72dpi.jpg
Xylem_tag_4c_wClearSpace.ai
Xylem_tag_4c_wClearSpace.eps
Documents: Application Reports / Case Studys
Application note A202001, German, "Alyza IQ PO4 auf Kläranlagen unterschiedlicher Ausbaugrößen"WTW phosphate analyzer Alyza IQ PO4
Application note A202001, EnglishWTW phosphate analyzer Alyza IQ PO4
IN THE OUTLET OF A FERTILIZER MANUFACTURER IN NORWAYApplication Note
IM ABLAUF EINES DÜNGEMITTELFABRIKATIONSBETRIEBES IN NORWEGENApplication note
IN THE PROCESS WATER OF AN SB REACTORCase Study
ZUR MESSUNG VON AMMONIUM IM PROZESSWASSER EINES SB-REAKTORSCase Study, German
Determination of Fe2+ next to Fe3+ (cerimetric)In samples that contain both iron (II) and iron (III) ions, the content of Fe2+ in addition to Fe3+ can be determined by titration with Cerium (IV) sulfate.
Titration Determination of Fe3+ (complexometric)Iron (3) forms a very stable complex with EDTA even at low pH Values.
Titration of alkalinity p+m value (Temporary hardness),Application note
Application note - English